Silicon Labs /Series1 /EFM32GG11B /EFM32GG11B420F2048GL112 /EMU /R5VCTRL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as R5VCTRL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (BYPASS)BYPASS 0 (EM4WUEN)EM4WUEN 0 (IMONEN)IMONEN 0 (AUTO)INPUTMODE

INPUTMODE=AUTO

Description

5V Regulator Control

Fields

BYPASS

5V Regulator Bypass

EM4WUEN

Enable EM4 Wakeup Due to VBUS Detection

IMONEN

Enable the Regulator Current Monitor for Selected Current Path to Either VREGI or VBUS

INPUTMODE

5V Input Mode

0 (AUTO): Regulator input supply switched automatically to the highest voltage of either VBUS or VREGI

1 (VBUS): Force VBUS pin as the regulator input

2 (VREGI): Force VREGI pin as the regulator input

Links

() ()